Sending unit

Just bench test it before installing. Read ohms empty and full moving the float arm up and down
The ohms will be 10 to 70 but the sweep needs to follow a curve not be linear.

Case in point, if at 1/2 tank, (not the sweep arm being 1/2 way in its travel) the sender reads about 23 ohms your better off, but it will read around 40 so it will look like 3/4.

It all in the graphs