Chasing this cooling issue for months

Take the T-stat out. or just use your old one. fill a pan with water,put the t-stat in and heat it on your stove. have some way of messuring water temp. observe at what temp the t-stat opens then slowly cool the water and observe when the t-stat closes. there could be a 20deg diffrence between open temp and close temp. Let us know your findings.