Wideband

I have an Innovate LM-1. The sensor should be as close as posible to the exhaust manifold/headers. If you're carburated you can't change anything except the overall mixture. Put it in the headpipe just behind the exhaust manifold. Be sure that it is placed between 12-3 or 9-12, if not it will collect moisture and go bad.