Voltage regulator upgrade? Keep frying voltage regulators with swap

Did I misunderstand? I thought you said you had to cut ALL wires, that is, the main battery wire? to stop it charging. This sounds more like how a "one wire" with integral regulator would act

Here's the thing...........if a typical isolated field unit is charging out of control, one which uses an external regulator, you should be able to disconnect EITHER field wire to stop it charging.

If you did that, and it continues to charge, then the regulator is NOT the cause.

The problem for me is I don't have documentation on any of this "new" stuff.

Your diagram is not proof that the regulator "was" in the PCM

You are correct - Unplugged the VR and it kept charging (12v going to one of the field terminals, other 'disconnected'. I didn't think that through.

Better look at my wiring and make sure that second wire isn't grounding itself.