318 hydraulic lifter preload.

I'll see if I can put this in a format that's not too confusing.


#8 E. .026 I. .048 #7 E. .005 I. .035
#6 I. .024 E. .040 #5 I. .025 E. .013
#4 E. .017 I. .012 #3 E. .005 I. .016
#2 I. .026 E. <.006 #1 I. .023 E. .013

The <.006 could be binding on the retainer. The .005 is because there is very little resistance but it still grabs the wire.

I used a set of tip cleaners as feeler gauges because it's very difficult to get a feeler gauge in there. Bent the wire to fit in there with as little deflection as possible.