figuring compression help needed.

P4452761 is a 110LSA hydro, so
At 9.22 and in at 108,
Static compression ratio of 9.22:1.
Ica of 62*, 700ft

Effective stroke is 2.84 inches.
Your dynamic compression ratio is 7.52:1 .
Your dynamic cranking pressure is 147.10 PSI.......................... 147
V/P (Volume to Pressure Index) is 127..................................... 127
But being a DC cam the the closing ramp is gonna be really long, and the Wallace calculator cannot correct for that.
Here is what it might actually look like; I added 4* to the Ica, and changed nothing else
Static compression ratio of 9.22:1.
Ica of 66*, 700ft

Effective stroke is 2.74 inches.
Your dynamic compression ratio is 7.29:1 .
Your dynamic cranking pressure is 141.07 PSI.......................... 141
V/P (Volume to Pressure Index) is 118 ..................................... 118
This is still not 100% accurate, just a guess.
Those numbers mean the bottom end, below 3000/3500 is gonna feel like an old 2bbl smogger teen from say 1973
So IMO, this combo does not have near enough compression to combo with a 2500TC and 3.55s........ on the street