Charging System Question

Field intensity increases with amp-turns. That is product of current and winding count. There is a limit, due to saturation of magnetic circuit.

Increased field, increases alternator output voltage, but output current, is load related.
Regulator action controls field current dynamically, and regulates voltage as necessary for RPM, load, and voltage drop variations.