No.
The ignition switch Start terminal supplies power to trigger the starter relay.
Ignition 2 terminal supplies the coil.
Wire S2 (yellow) carries current to the relay.
Wire J3 (brown) carries current to the coil when the points are closed.
System voltage is noticibly drawn down when the starter engages.